3-Phase Split Phase Measuring Energy Meter |
 |
|

|
|
 |
Technical parameters: 1) Standard: IEC62052-11, IEC62053-21, IEC62053-23 2) Rated voltage: 3 x 220 / 380V, 3 x 57.7 / 100V, 3 x 100V 3) Rated current: 1.5(6) A, 5(10) A, 10(40) A, 10(60) A, 20(80) A, 30(100) A 4) Accuracy: active Class 1.0, reactive Class 2.0 5) Power loss: ?1.5W 6) Clock error: ?0.5s/D (23±3° C) 7) Backup lithium battery working life: > 10 years; continuous working time: > 3 years (split phase energy multi-function meter) 8) Working frequency range: 50Hz±5% 9) Working ambient temperature: -20~55° C 10) Has infrared and RS485 interface, with the communication protocol conforming to DL/T645-1997 Main functions of three phase split phase measuring multi-function electric energy meter (DTSD581): 1) Measure energy: measures total, peak, shoulder and trough accumulative active energy of three phase, measures total, peak, shoulder and trough active energy of phase A, B and C respectively, and measure total reactive energy and reactive energy of phase A, B and C respectively. The record content is current and previous six months 2) Measure demand: measures total maximum demand and the occurred time of active energy for current and previous 6 months 3) Tariff and time period: three tariffs for active energy (peak, shoulder and trough), and can set at most 8 time periods per day 4) Real time data: voltage and current for phase A, B and C respectively, and active power, reactive power and power factor for each phase and total 5) Records the latest ten times of starting and ending time of the power off for the electric meter 6) Records each phase's phase loss accumulative time and times and its latest ten times of starting and ending time 7) Records the accumulative time of the cover opening and the latest opening time 8) Has key-press display and automatic recycle display and the recycle display content and time can be set 9) Records the load curve: selected from the total active energy and total reactive energy, and the recording time interval can be set 10) Freezes billing readings on reading date at the end of a month, and also can use broadcasting order to freeze the energy for current uniformly 11) Has controlling function: the output relay controlling interface is used to control external device Main functions of split phase measuring common meter (DTS581): 1) Records current three phase accumulative forward active total energy and reverse active total energy, forward active energy of phase A, B and C respectively, three phase accumulative forward inductive reactive energy (quadrant 1), and forward reactive energy (quadrant 1+4) 2) Broadcasts the frozen energy
Please use contact form for send message directly to seller. Your message will be sent directly to the recipient and will not be publicly displayed. |
|